| SPECIFICATIONS
|
||
| MULTIZONE
SUPERVISION CONTROL PANEL |
||
| MODEL CP-224 | BASIC MODEL | ( 6 to 48 zones AND MORE) |
| MODEL CP-224-CC | COMMUNICATION WITH COMPUTER | ( 6 to 48 zones AND MORE) |
| MODEL CP-224-CVC | COMMUNICATION WITH COMPUTER + VALVE CONTROL | ( 6 to 48 zones AND MORE) |
| |
![]() ![]() ![]() ![]() ![]() |
||||
| FEATURES: | According your needs: | ![]() |
|||
| Internal buzzer | |||||
| 3 relays (auxiliary outputs) | 6 ZONES | ||||
| Backup battery 12 Volts DC | 12 ZONES | ||||
| Valve status indicator ( opened or closed) | 18 ZONES | ||||
| Allows the protection of a minimum of 6 zones | 24 ZONES | ||||
| Up to 48 outputs connections for valve monitoring. | 30 ZONES | ||||
| Alarm events location in alphanumeric text. | 36 ZONES | ||||
| Connection of 30 detectors and more per zone. | 42 ZONES | ||||
| 48 ZONES | |||||
| and more.... | MODEL
CP-224 |
||||
| Capable of up to 48 alarm events with automatic valves closing. | |||||
| Serial communication port for connection to a Personal Computer. | |||||
| AQUA-STOP® windows monitoring software supplied with the system. | |||||
| Detection and wiring status transmitted continuously to Personal Computer via serial link. | |||||
| Can accept valve close commands from a local Personal Computer via serial link. | |||||
| Status monitoring and valve close commands can be relayed to / from a Personal Computer | |||||
| Connected to the local Personal Computer via Internet. | |||||
|
Computer report: AQUA-STOP®
SOFTWARE |
![]() |
| SOFTWARE (SERVER / CLIENT) | |
| Enhanced graphical user interface with Real Time graphical screen. | |
| Data logging fonction for all alarm events and valves status. | |
| Real time report of detection / fault / communication failure. | |
| Works with Microsoft Windows 95, 98, Millennium, NT and X.P | |
| Description of zones ( editable) | |
| ALARM EVENTS: | |
| Water detection. | |
| Detectors wiring failure. | |
| Wiring fault on AQUA-STOP valve circuitry. | |
| Communication failure with Panel/ Server/Client . |
![]() |
|
GENERAL SPECIFICATIONS:
|
||||
| Enclosure: | ||||
| Wall mount steel cabinet, key-lockable. | ||||
| Color: Blue | ||||
| Dimensions: | ||||
| Height: 28 in. / 71 cm. | ||||
| Width: 20 in. / 51cm | ||||
| Depth: 7.5 in. / 19 cm. | ||||
| Micro-Processor based control: | ||||
| Monitors 1-48 Zones /input. | ||||
| Monitors each zone independently. | ||||
| Identifies location, time , date, of all alarm events in real time. | ||||
| Identifies the number of valves installed and the number of zones controlled. | ||||
| Allows the closing of valves by a remote computer connected to the local PC computer via Internet. | ||||
| Displays alarm (Fuse failure on valves circuitry) | ||||
| Operating voltage: | ||||
| Supply voltage standard: AC 230 Volts /50 HzAC 120 Volts /60 Hz. | ||||
| Power transformer output: 28 VAC, 100VA, 4 AMP. (UL Listed, CSA Approved) | ||||
| Power supply /charger : 12 Volts DC @ 4 AMP. | ||||
| Battery backup. | ||||
| Power consumption: | ||||
| From supply voltage standard: | In Standby: 270 mA. At 120 Volts AC | |||
| In detection ( valve activated): 2 A. ( during 1.2 sec. )at 120 VAC. | ||||
| From the battery back up: 12 Volts DC | In Standby: 550 mA | |||
| In detection (valve activated): 2 A. ( during 1.2 sec. ) | ||||
| Motherboard / Extension Cards | ||||
| Primary circuit: 12 Volts DC ( Supplies the valves circuitry) | ||||
| Secondary circuit: 5 Volts DC ( Supplies the micro processor circuitry) | ||||
| 8 slots allowing 8 pcboardsextension cards | ||||
| Minimum installation: 1 extension card = 6 zones. | ||||
| Inputs: | ||||
| Minimum 6 to 48 maximum inputs for water detection terminals for one control panel. | ||||
| Minimum 6 to 48 maximum inputs for wire fault terminals for one control panel. | ||||
| Minimum 6 to 48 maximum inputs for valve status ( closed or opened) for one control panel. | ||||
| Outputs: | ||||
| 6 to 48 outputs 12 volts DC, for supplying AQUA-STOP valves or for alarm connections on optional relays. | ||||
| 3 relays : SPDT Form C,N.O. , 0.6A @125VAC, 2A. @30 VDC | ||||
| 1st. relay is used for the telephone dialer (optional): AUTOMATIC DIAL-OUT. | ||||
| Dials up to 4 different remote telephones/ dial a pager. | ||||
| 2nd relay (auxiliary) may be used to connect the panel to another security system installation. | ||||
| 3rd relay ( auxiliary)
may be used to activate an external horn. | ||||
| VISUAL REPORT/ ALARM INDICATORS: | ||||
| LED status indicators: | ||||
| Blue: Micro processor alimentation | ||||
| Red: Water Detection event | ||||
| Red: Wirefault event | ||||
| Red: Valve status closed / non- closing | ||||
| ALARM button /to mute the internal buzzer | ||||
| RESET button/ to reset the system after curing the detection/wirefault event. | ||||
| LCD Display- Alphanumeric: | ||||
| Alarm and fault location | ||||
| Number of Zones | ||||
| Number of Valves | ||||
| Audible alarm: | ||||
| Internal buzzer (silenced by the alarm button) | ||||
| Serial interface RS-232 | ||||
| Connection on local computer | ||||
| Computer report: | ||||
| Multi zone Supervision control panel software ( server /client) | ||||
| Report in real time of alarm events. | ||||
| Description of zones ( editable) | ||||
| Enhanced graphical user interface. | ||||
| Data logging fonction enables to log activity of the panel, alarm events and valve status. | ||||
| Works with Microsoft Windows 95, 98, Millennium, NT and XP. | ||||
| Alarm events via computer: | ||||
| Water
detection. | ||||
| Wiring
detectors failure. | ||||
| Communication failure with Panel/ Server/Client . | ||||
| Wiring fault with AQUA-STOP valves. | ||||
| Internet communication: ( Application Client) | ||||
| Password protected. | ||||
| Multiple clients connected to server. | ||||
| Indicator of status of connection with the server. | ||||
| Report in real time of detection / fault/ communication failure. | ||||
| Alert message displayed in detection / fault event. | ||||
| Audible Alert Sound activated in detection / fault event. | ||||
| Description of zones. | ||||
| Closing of valves. ( Valves may be closed via internet) | ||||
| System integrity: | ||||
| Internal micro processor watchdog. | ||||
| External micro processor supervisory circuit. | ||||
| Other specifications: | ||||
| Wiring distance for detectors: Up to 3000 feet. | ||||
| Wiring distance for valve control: Will vary between400 and 600 feet and more. * | ||||
| *( Depending the length of wire used the wire gauge has to be considered due to the voltage drop) | ||||
| Recommended wire gauge for detectors network: AWG #22 (Telephone cable). | ||||
| Detectors connection on each zone: In parallel. | ||||
| Capacity – detectors / zone: Up to 30 detectors. | ||||
| Water detectors: | ||||
| Model DF1 (flexible detector) | Plastic strips Self –adhesive, (2.5 inch length x 0.5 inch width x 0.010 inch thick) | |||
| Two probes: Conductive silver ink circuitry. (width 0.100 inch) | ||||
| Wires crimped on the detector with two brass connectors.(included) | ||||
| Distance between two probes: 0.125 inch | ||||
| Model DS2 (Solid detector) | Nylon solid block, secured by two screws or self-adhesive at the back. | |||
| Dimensions: 2.5 inch Length x 0.5 inch Width x 0.5 inch Height. | ||||
| Two probes: Binder post aluminium. | ||||
| Wires secured on the detector by two aluminium
screws. | ||||
| Distance between two probes: 0.750 inch. | ||||